GSO IEC 62368-1:2024
GSO - Cover page
Gulf Foreword
IEC - Cover page
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
 3.1 Energy source abbreviated terms
 3.2 Other abbreviated terms
 3.3 Terms and definitions
  3.3.1 Circuit terms
  3.3.2 Enclosure terms
  3.3.3 Equipment terms
  3.3.4 Flammability terms
  3.3.5 Electrical insulation
  3.3.6 Miscellaneous
  3.3.7 Operating and fault conditions
  3.3.8 Persons
  3.3.9 Potential ignition sources
  3.3.10 Ratings
  3.3.11 Safeguards
  3.3.12 Spacings
  3.3.13 Temperature controls
  3.3.14 Voltages and currents
  3.3.15 Classes of equipment with respect to protection from electric shock
  3.3.16 Chemical terms
  3.3.17 Batteries
  3.3.18 FIW terms
  3.3.19 Sound exposure
4 General requirements
 4.1 General
  4.1.1 Application of requirements and acceptance of materials, components and subassemblies
  4.1.2 Use of components
  4.1.3 Equipment design and construction
  4.1.4 Equipment installation
  4.1.5 Constructions and components not specifically covered
  4.1.6 Orientation during transport and use
  4.1.7 Choice of criteria
  4.1.8 Liquids, refrigerants and liquid filled components (LFCs)
  4.1.9 Electrical measuring instruments
  4.1.10 Temperature measurements
  4.1.11 Steady state conditions
  4.1.12 Hierarchy of safeguards
  4.1.13 Examples mentioned in this document
  4.1.14 Tests on parts or samples separate from the end-product
  4.1.15 Markings and instructions
 4.2 Energy source classifications
  4.2.1 Class 1 energy source
  4.2.2 Class 2 energy source
  4.2.3 Class 3 energy source
  4.2.4 Energy source classification by declaration
 4.3 Protection against energy sources
  4.3.1 General
  4.3.2 Safeguards for protection of an ordinary person
  4.3.3 Safeguards for protection of an instructed person
  4.3.4 Safeguards for protection of a skilled person
  4.3.5 Safeguards in a restricted access area
 4.4 Safeguards
  4.4.1 Equivalent materials or components
  4.4.2 Composition of a safeguard
  4.4.3 Safeguard robustness
  4.4.4 Displacement of a safeguard by an insulating liquid
  4.4.5 Safety interlocks
 4.5 Explosion
  4.5.1 General
  4.5.2 Requirements
 4.6 Fixing of conductors and conductive parts
  4.6.1 Requirements
  4.6.2 Compliance criteria
 4.7 Equipment for direct insertion into mains socket-outlets
  4.7.1 General
  4.7.2 Requirements
  4.7.3 Compliance criteria
 4.8 Equipment containing coin or button cell batteries
  4.8.1 General
  4.8.2 Instructional safeguard
  4.8.3 Construction
  4.8.4 Tests
  4.8.5 Compliance criteria
 4.9 Likelihood of fire or shock due to entry of conductive objects
 4.10 Components requirements
  4.10.1 Disconnect device
  4.10.2 Switches and relays
  4.10.3 Mains power supply cords
  4.10.4 Batteries and their protection circuits
5 Electrically-caused injury
 5.1 General
 5.2 Classification and limits of electrical energy sources
  5.2.1 Electrical energy source classifications
  5.2.2 Electrical energy source ES1 and ES2 limits
 5.3 Protection against electrical energy sources
  5.3.1 General
  5.3.2 Accessibility to electrical energy sources and safeguards
 5.4 Insulation materials and requirements
  5.4.1 General
  5.4.2 Clearances
  5.4.3 Creepage distances
  5.4.4 Solid insulation
  5.4.5 Antenna terminal insulation
  5.4.6 Insulation of internal wire as a part of a supplementary safeguard
  5.4.7 Tests for semiconductor components and for cemented joints
  5.4.8 Humidity conditioning
  5.4.9 Electric strength test
  5.4.10 Safeguards against transient voltages from external circuits
  5.4.11 Separation between external circuits and earth
  5.4.12 Insulating liquid
 5.5 Components as safeguards
  5.5.1 General
  5.5.2 Capacitors and RC units
  5.5.3 Transformers
  5.5.4 Optocouplers
  5.5.5 Relays
  5.5.6 Resistors
  5.5.7 Surge suppressors
  5.5.8 Insulation between the mains and an external circuit consisting of a coaxial cable
  5.5.9 Safeguards for socket-outlets in outdoor equipment
 5.6 Protective conductor
  5.6.1 General
  5.6.2 Requirements for protective conductors
  5.6.3 Requirements for protective earthing conductors
  5.6.4 Requirements for protective bonding conductors
  5.6.5 Terminals for protective conductors
  5.6.6 Resistance of the protective bonding system
  5.6.7 Reliable connection of a protective earthing conductor
  5.6.8 Functional earthing
 5.7 Prospective touch voltage, touch current and protective conductor current
  5.7.1 General
  5.7.2 Measuring devices and networks
  5.7.3 Equipment set-up, supply connections and earth connections
  5.7.4 Unearthed accessible parts
  5.7.5 Earthed accessible conductive parts
  5.7.6 Requirements when touch current exceeds ES2 limits
  5.7.7 Prospective touch voltage and touch current associated with external circuits
  5.7.8 Summation of touch currents from external circuits
 5.8 Backfeed safeguard in battery backed up supplies
6 Electrically-caused fire
 6.1 General
 6.2 Classification of power sources and potential ignition sources
  6.2.1 General
  6.2.2 Power source circuit classifications
  6.2.3 Classification of potential ignition sources
 6.3 Safeguards against fire under normal operating conditions and abnormal operating conditions
  6.3.1 Requirements
  6.3.2 Compliance criteria
 6.4 Safeguards against fire under single fault conditions
  6.4.1 General
  6.4.2 Reduction of the likelihood of ignition under single fault conditions in PS1 circuits
  6.4.3 Reduction of the likelihood of ignition under single fault conditions in PS2 circuits and PS3 circuits
  6.4.4 Control of fire spread in PS1 circuits
  6.4.5 Control of fire spread in PS2 circuits
  6.4.6 Control of fire spread in a PS3 circuit
  6.4.7 Separation of combustible materials from a PIS
  6.4.8 Fire enclosures and fire barriers
  6.4.9 Flammability of an insulating liquid
 6.5 Internal and external wiring
  6.5.1 General requirements
  6.5.2 Requirements for interconnection to building wiring
  6.5.3 Internal wiring for socket-outlets
 6.6 Safeguards against fire due to the connection of additional equipment
7 Injury caused by hazardous substances
 7.1 General
 7.2 Reduction of exposure to hazardous substances
 7.3 Ozone exposure
 7.4 Use of personal safeguards or personal protective equipment (PPE)
 7.5 Use of instructional safeguards and instructions
8 Mechanically-caused injury
 8.1 General
 8.2 Mechanical energy source classifications
  8.2.1 General classification
  8.2.2 MS1
  8.2.3 MS2
  8.2.4 MS3
 8.3 Safeguards against mechanical energy sources
 8.4 Safeguards against parts with sharp edges and corners
  8.4.1 Requirements
  8.4.2 Compliance criteria
 8.5 Safeguards against moving parts
  8.5.1 Requirements
  8.5.2 Instructional safeguard requirements
  8.5.3 Compliance criteria
  8.5.4 Special categories of equipment containing moving parts
  8.5.5 High pressure lamps
 8.6 Stability of equipment
  8.6.1 Requirements
  8.6.2 Static stability
  8.6.3 Relocation stability
  8.6.4 Glass slide test
  8.6.5 Horizontal force test and compliance criteria
 8.7 Equipment mounted to a wall, ceiling or other structure
  8.7.1 Requirements
  8.7.2 Test methods
  8.7.3 Compliance criteria
 8.8 Handle strength
  8.8.1 General
  8.8.2 Test method
 8.9 Wheels or casters attachment requirements
  8.9.1 General
  8.9.2 Test method
 8.10 Carts, stands, and similar carriers
  8.10.1 General
  8.10.2 Marking and instructions
  8.10.3 Cart, stand or carrier loading test and compliance criteria
  8.10.4 Cart, stand or carrier impact test
  8.10.5 Mechanical stability
  8.10.6 Thermoplastic temperature stability
 8.11 Mounting means for slide-rail mounted equipment (SRME)
  8.11.1 General
  8.11.2 Requirements
  8.11.3 Mechanical strength test
  8.11.4 Compliance criteria
 8.12 Telescoping or rod antennas
9 Thermal burn injury
 9.1 General
 9.2 Thermal energy source classifications
  9.2.1 TS1
  9.2.2 TS2
  9.2.3 TS3
 9.3 Touch temperature limits
  9.3.1 Requirements
  9.3.2 Test method and compliance criteria
 9.4 Safeguards against thermal energy sources
 9.5 Requirements for safeguards
  9.5.1 Equipment safeguard
  9.5.2 Instructional safeguard
 9.6 Requirements for wireless power transmitters
  9.6.1 General
  9.6.2 Specification of the foreign objects
  9.6.3 Test method and compliance criteria
10 Radiation
 10.1 General
 10.2 Radiation energy source classifications
  10.2.1 General classification
  10.2.2 RS1
  10.2.3 RS2
  10.2.4 RS3
 10.3 Safeguards against laser radiation
 10.4 Safeguards against optical radiation from lamps and lamp systems (including LED types)
  10.4.1 General requirements
  10.4.2 Requirements for equipment safeguards
  10.4.3 Instructional safeguard
  10.4.4 Compliance criteria
 10.5 Safeguards against X-radiation
  10.5.1 Requirements
  10.5.2 Compliance criteria
  10.5.3 Test method
 10.6 Safeguards against acoustic energy sources
  10.6.1 General
  10.6.2 Classification
  10.6.3 Requirements for dose-based systems
  10.6.4 Measurement methods
  10.6.5 Protection of persons
  10.6.6 Requirements for listening devices (headphones, earphones, etc.)
Annex A (informative) Examples of equipment within the scope of this document
Annex B (normative) Normal operating condition tests, abnormal operating condition tests and single fault condition tests
Annex C (normative) UV radiation
Annex D (normative) Test generators
Annex E (normative) Test conditions for equipment intended to amplify audio signals
Annex F (normative) Equipment markings, instructions, and instructional safeguards
Annex G (normative) Components
Annex H (normative) Criteria for telephone ringing signals
Annex I (informative) Overvoltage categories (see IEC 60364-4-44)
Annex J (normative) Insulated winding wires for use without interleaved insulation
Annex K (normative) Safety interlocks
Annex L (normative) Disconnect devices
Annex M (normative) Equipment containing batteries and their protection circuits
Annex N (normative) Electrochemical potentials (V)
Annex O (normative) Measurement of creepage distances and clearances
Annex P (normative) Safeguards against conductive objects
Annex Q (normative) Circuits intended for interconnection with building wiring
Annex R (normative) Limited short-circuit test
Annex S (normative) Tests for resistance to heat and fire
Annex T (normative) Mechanical strength tests
Annex U (normative) Mechanical strength of CRTs and protection against the effects of implosion
Annex V (normative) Determination of accessible parts
Annex W (informative) Comparison of terms introduced in this document
Annex X (normative) Alternative method for determining clearances for insulation in circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)
Annex Y (normative) Construction requirements for outdoor enclosures
Bibliography
30mm
20mm
15mm
15mm
10mm
17mm
Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
GSO IEC 62368-1:2024Gulf Standard
GSO IEC 62368-1:2024
IEC 62368-1:2023
مواصفة قياسية خليجية
معدات تقنية المعلومات والاتصالات، السمعية/المرئية - الجزء 1: متطلبات السلامة
Gulf Standard
Audio/video, information and communication technology equipment - Part 1: Safety requirements
ICS:
33.160.01 ; 35.020

graphic
هذه الوثيقة محمية بالقانون
COPYRIGHT PROTECTED DOCUMENT
جميع الحقوق محفوظة لهيئة لتقييس لدول مجلس التعاون لدول الخليج العربية.
ما لم ينص على خلاف ذلك، لا يجوز إعادة إنتاج أي جزء من هذا المنشور أو استخدامه بأي شكل آخر أو بأي وسيلة، إلكترونية أو ميكانيكية، بما في ذلك التصوير، أو النشر على الإنترنت أو الإنترانت، دون إذن كتابي مسبق من هيئة التقييس لدول مجلس التعاون لدول الخليج العربية على العنوان أدناه أو الدول الأعضاء في الهيئة داخل بلدانهم.
All rights reserved to GCC Standardization Organization (GSO). Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either GSO at the address below or GSO's member body in the country of the requester.
Outreach Dept, Knowledge Management Section
GCC Standardization Organization (GSO)
P.O.Box: 85245 Riyadh 12511
Kingdom of Saudi Arabia
إدارة التواصل، قسم إدارة المعرفة
هيئة التقييس لدول مجلس التعاون لدول الخليج العربية (GSO)
ص. ب: 85245 الرياض 12511
المملكة العربية السعودية
Tel: +966115208000 :هاتف
Fax: +966115208010 :فاكس
E-Mail: csc@gso.org.sa :بريد إلكتروني
Website: www.gso.org.sa :موقع ويب
30mm
20mm
15mm
15mm
10mm
17mm

Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
GSO IEC 62368-1:2024Gulf Standard

Gulf Foreword

GCC Standardization Organization (GSO) is a regional organization which consists of the national standardization bodies of GCC member states. One of GSO main functions is to issue gulf standards and technical regulations through specialized technical committees.
GSO Technical Council in its meeting number (57) held on 20/07/1445 H, which corresponds to 31/01/2024, has approved the update of Gulf Standard GSO IEC 62368-1:2024 titled "Audio/video, information and communication technology equipment - Part 1: Safety requirements" in English language which was studied and adopted by endorsement from International Electrotechnical Commission Standard IEC 62368-1:2023 through the technical program of GSO Technical Committee for Electrical and Electronic Products (TC03) in SAUDI ARABIA schedule . This document will cancel and replace the Gulf Standard GSO IEC 62368-1:2010.
تقديم خليجي
هيئة التقييس لدول مجلس التعاون لدول الخليج العربية هيئة إقليمية تضم في عضويتها أجهزة التقييس الوطنية في الدول الأعضاء ، ومن مهام الهيئة إعداد المواصفات القياسية واللوائح الفنية الخليجية بواسطة لجان فنية متخصصة.
قرر المجلس الفني لهيئة التقييس لدول مجلس التعاون لدول الخليج العربية في الاجتماع الـ (57) بتاريخ 1445/07/20 هـ ،الموافق 2024/01/31م اعتماد تحديث المواصفة القياسية الخليجية رقم GSO IEC 62368-1:2024 وعنوانها "معدات تقنية المعلومات والاتصالات، السمعية/المرئية - الجزء 1: متطلبات السلامة" باللغة الانجليزية التي تم دراستها وتبنيها بالمصادقة عن اللجنة الدولية الكهروتقنية رقم IEC 62368-1:2023 ضمن برنامج عمل اللجنة الفنية الخليجية للمواصفات الكهربائية والإلكترونية (TC03) المدرجة في خطة المملكة العربية السعودية . على أن تلغي وتحل محل المواصفة القياسية رقم GSO IEC 62368-1:2010 .
30mm
20mm
15mm
15mm
10mm
17mm
Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
GSO IEC 62368-1:2024Gulf Standard
IEC 62368-1

INTERNATIONAL

STANDARD

Edition 4.0  2023-05
Audio/video, information and communication technology equipment –
Part 1: Safety requirements
IEC 62368-1:2023 ED4
30mm
20mm
15mm
15mm
10mm
17mm
Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
GSO IEC 62368-1:2024Gulf Standard
THIS PUBLICATION IS COPYRIGHT PROTECTEDCopyright © 2023 IEC, Geneva, Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or your local IEC member National Committee for further information.
IEC Secretariat3, rue de VarembéCH-1211 Geneva 20Switzerland Tel.: +41 22 919 02 11 info@iec.ch www.iec.ch
About the IEC The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the latest edition, a corrigendum or an amendment might have been published.
IEC publications search - webstore.iec.ch/advsearchform The advanced search enables to find IEC publications by a variety of criteria (reference number, text, technical committee, ...). It also gives information on projects, replaced and withdrawn publications. IEC Just Published - webstore.iec.ch/justpublished Stay up to date on all new IEC publications. Just Published details all new publications released. Available online and once a month by email. IEC Customer Service Centre - webstore.iec.ch/csc If you wish to give us your feedback on this publication or need further assistance, please contact the Customer Service Centre: sales@iec.ch .   IEC Products & Services Portal - products.iec.ch Discover our powerful search engine and read freely all the publications previews. With a subscription you will always have access to up to date content tailored to your needs. Electropedia - www.electropedia.org The world's leading online dictionary on electrotechnology, containing more than 22 300 terminological entries in English and French, with equivalent terms in 19 additional languages. Also known as the International Electrotechnical Vocabulary (IEV) online.
30mm
20mm
15mm
15mm
10mm
17mm
Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
GSO IEC 62368-1:2024Gulf Standard
IEC 62368-1

INTERNATIONAL

STANDARD

Edition 4.0  2023-05
Audio/video, information and communication technology equipment –
Part 1: Safety requirements

INTERNATIONAL

ELECTROTECHNCIAL

COMMISSION


ICS 33.160.01, 35.020ISBN 9782832270196Warning! Make sure that you obtained this publication from an authorized distributor.© Registered trademark of the International Electrotechnical Commission
30mm
20mm
15mm
15mm
10mm
17mm

Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
GSO IEC 62368-1:2024Gulf Standard
CONTENTS
INTERNATIONAL ELECTROTECHNICAL COMMISSION
International StandardIEC 62368-1:2023 ED4
Audio/video, information and communication technology equipment - Part 1: Safety requirements

FOREWORD

1)
The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as "IEC Publication(s)"). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2)
The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees.
3)
IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user.
4)
In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5)
IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any services carried out by independent certification bodies.
6)
All users should ensure that they have the latest edition of this publication.
7)
No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8)
Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication.
9)
Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
IEC 62368-1 has been prepared by IEC technical committee TC 108: Safety of electronic equipment within the field of audio/video, information technology and communication technology. It is an International Standard.
This fourth edition cancels and replaces the third edition published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a)
new table with requirements for external circuits;
b)
revision of requirements for openings in fire enclosures;
c)
revision of requirements for liquid filled components;
d)
revision of battery charging requirements.
The text of this International Standard is based on the following documents:
Draft Report on voting
108/800/FDIS 108/804/RVD
Full information on the voting for its approval can be found in the report on voting indicated in the above table.
The language used for the development of this International Standard is English.
This document was drafted in accordance with ISO/IEC Directives, Part 2, and developed in accordance with ISO/IEC Directives, Part 1 and ISO/IEC Directives, IEC Supplement, available at www.iec.ch/members_experts/refdocs. The main document types developed by IEC are described in greater detail at www.iec.ch/publications.
A list of all parts in the IEC 62368 series, published under the general title Audio/video, information and communication technology equipment, can be found on the IEC website.
The "in some countries" notes regarding differing national practices are contained in the following clauses, subclauses and tables:
0.2.1, Clause 1, 3.3.8.1, 3.3.8.3, 4.1.15, 4.7.3, 5.4.2.3.2.4, 5.4.2.5, 5.4.5.1, 5.4.10.2.1, 5.4.10.2.2, 5.4.10.2.3, 5.5.2.1, 5.5.6, 5.6.4.2.1, 5.6.8, 5.7.6, 5.7.7.1, 8.5.4.2.3, 10.5.3, 10.6.1, F.3.3.4, F.3.3.6, Y.4.1, Y.4.5, Table 12, Table 13 and Table 38.
In this document, the following print types or formats are used:
-
requirements proper and normative annexes: in roman type;
-
compliance statements and test specifications: in italic type;
-
notes/explanatory matter: in smaller roman type;
-
normative conditions within tables: in smaller roman type;
-
terms that are defined in 3.3: bold.
In figures and tables, if colour is available:
-
green colour denotes a class 1 energy source;
-
yellow colour denotes a class 2 energy source;
-
red colour denotes a class 3 energy source.
A comparison of terms introduced in this document that are different from other existing IEC documents is given in Annex W.
The committee has decided that the contents of this document will remain unchanged until the stability date indicated on the IEC website under webstore.iec.ch in the data related to the specific document. At this date, the document will be
•
reconfirmed,
•
withdrawn,
•
replaced by a revised edition, or
•
amended.
NOTEExplanatory information related to IEC 62368-1 is contained in IEC TR 62368-2. It provides rationale together with explanatory information related to this document.
IMPORTANTThe "colour inside" logo on the cover page of this document indicates that it contains colours which are considered to be useful for the correct understanding of its contents. Users should therefore print this document using a colour printer.

INTRODUCTION

0Principles of this product safety standard

0.1Objective

This part of IEC 62368 is a product safety standard that classifies energy sources, prescribes safeguards against those energy sources, and provides guidance on the application of, and requirements for, those safeguards.
The prescribed safeguards are intended to reduce the likelihood of pain, injury and, in the case of fire, property damage.
The objective of the introduction is to help designers to understand the underlying principles of safety in order to design safe equipment. These principles are informative and not an alternative to the detailed requirements of this document.

0.2Persons

0.2.1General

This document describes safeguards for the protection of three kinds of persons: the ordinary person, the instructed person, and the skilled person. Unless otherwise specified in this document, the requirements for an ordinary person apply. This document assumes that a person will not intentionally create conditions or situations that could cause pain or injury.
NOTE 1In Australia, the work conducted by an instructed person or skilled person can require formal licensing from regulatory authorities.
NOTE 2In Germany, a person can only be regarded as an instructed person or a skilled person if certain legal requirements are fulfilled.

0.2.2Ordinary person

Ordinary person is the term applied to all persons other than instructed persons and skilled persons. Ordinary persons include not only users of the equipment, but also all persons who can possibly have access to the equipment or who could be in the vicinity of the equipment. Under normal operating conditions or abnormal operating conditions, ordinary persons should not be exposed to parts comprising energy sources capable of causing pain or injury. Under a single fault condition, ordinary persons should not be exposed to parts comprising energy sources capable of causing injury.

0.2.3Instructed person

Instructed person is a term applied to persons who have been instructed and trained by a skilled person, or who are supervised by a skilled person, to identify energy sources that can cause pain (see Table 1) and to take precautions to avoid unintentional contact with or exposure to those energy sources. Under normal operating conditions, abnormal operating conditions or single fault conditions, instructed persons should not be exposed to parts comprising energy sources capable of causing injury.

0.2.4Skilled person

Skilled person is a term applied to persons who have training or experience in the equipment technology, particularly in knowing the various energies and energy magnitudes used in the equipment. Skilled persons are expected to use their training and experience to recognize energy sources capable of causing pain or injury and to take action for protection from injury from those energies. Skilled persons should also be protected against unintentional contact or exposure to energy sources capable of causing injury.

0.3Model for pain and injury

An energy source that causes pain or injury does so through the transfer of some form of energy to or from a body part.
This concept is represented by a three-block model (see Figure 1).
Figure 1 — Three block model for pain and injury
graphic
This safety standard specifies three classes of energy sources defined by magnitudes and durations of source parameters relative to the body responses to those electrical and thermal energy sources (see Table 1). Source parameters relative to responses to combustible material, mechanical energy sources and radiation energy sources are specified based on experience and basic safety standards.
Table 1 — Response to energy class
Energy source Effect on the body Effect on combustible materials
Class 1 Not painful, but can be detectable Ignition not likely
Class 2 Painful, but not an injury Ignition possible, but limited growth and spread of fire
Class 3 Injury Ignition likely, rapid growth and spread of fire
The energy threshold for pain or injury is not constant throughout the population. For example, for some energy sources, the threshold is a function of body mass; the lower the mass, the lower the threshold, and vice-versa. Other body variables include age, state of health, state of emotions, effect of drugs, skin characteristics, etc. Furthermore, even where outward appearances otherwise appear equal, individuals differ in their thresholds of susceptibility to the same energy source.
The effect of duration of energy transfer is a function of the specific energy form. For example, pain or injury from thermal energy can be very short (1 s) for high skin temperature, or very long (several hours) for low skin temperature.
Furthermore, the pain or injury can occur some considerable time after the transfer of energy to a body part. For example, it is possible that pain or injury from some chemical or physiological reaction does not manifest itself for days, weeks, months, or years.

0.4Energy sources

Energy sources are addressed by this document, together with the pain or injury that results from a transfer of that energy to the body, and the likelihood of property damage that results from fire escaping the equipment.
An electrical product is connected to an electrical energy source (for example, the mains), an external power supply unit, or a battery. An electrical product uses the electrical energy to perform its intended functions.
In the process of using electrical energy, the product transforms the electrical energy into other forms of energy (for example, thermal energy, kinetic energy, optical energy, audio energy, electromagnetic energy, etc.). Some energy transformations can be a deliberate part of the product function (for example, moving parts of a printer, images on a visual display unit, sound from a speaker, etc.). Some energy transformations can be a by-product of the product function (for example, heat dissipated by functional circuits, X-radiation from a cathode-ray tube, etc.).
Some products can use energy sources that are non-electrical energy sources such as moving parts or chemicals. The energy in these other sources can be transferred to or from a body part, or can be transformed into other energy forms (for example, chemical energy can be converted to electrical energy through a battery, or a moving body part transfers its kinetic energy to a sharp edge).
Examples of the types of energy forms and the associated injuries and property damage addressed in this document are in Table 2.
Table 2 — Examples of body response or property damage related to energy sources
Forms of energy Examples of body response or property damage Clause
Electrical energy
(for example, energized conductive parts)
Pain, fibrillation, cardiac arrest, respiratory arrest, skin burn, or internal organ burn 5
Thermal energy
(for example, electrical ignition and spread of fire)
Electrically-caused fire leading to burn-related pain or injury, or property damage 6
Chemical reaction
(for example, electrolyte, poison)
Skin damage, organ damage, or poisoning 7
Kinetic energy
(for example, moving parts of equipment, or a moving body part against an equipment part)
Laceration, puncture, abrasion, contusion, crush, amputation, or loss of a limb, eye, ear, etc. 8
Thermal energy
(for example, hot accessible parts)
Skin burn 9
Radiated energy
(for example, electromagnetic energy, optical energy, acoustic energy)
Loss of sight, skin burn, or loss of hearing 10

0.5Safeguards

0.5.1General

Many products necessarily use energy capable of causing pain or injury. Product design cannot eliminate such energy use. Consequently, such products should use a scheme that reduces the likelihood of such energy being transferred to a body part. The scheme that reduces the likelihood of energy transfer to a body part is a safeguard (see Figure 2).
Figure 2 — Three block model for safety
graphic
A safeguard is a device or scheme or system that:
-
is interposed between an energy source capable of causing pain or injury and a body part, and
-
reduces the likelihood of transfer of energy capable of causing pain or injury to a body part.
NOTESafeguard mechanisms against transfer of energy capable of causing pain or injury include:
-
attenuating the energy (reduces the value of the energy); or
-
impeding the energy (slows the rate of energy transfer); or
-
diverting the energy (changes the energy direction); or
-
disconnecting, interrupting, or disabling the energy source; or
-
enveloping the energy source (reduces the likelihood of the energy from escaping); or
-
interposing a barrier between a body part and the energy source.
A safeguard can be applied to the equipment, to the local installation, to a person or can be a learned or directed behaviour (for example, resulting from an instructional safeguard) intended to reduce the likelihood of transfer of energy capable of causing pain or injury. A safeguard can be a single element or a set of elements.
Generally, this document uses an order of preference for providing safeguards based on the requirements given in ISO/IEC Guide 51 as follows:
-
equipment safeguards are always useful, since they do not require any knowledge or actions by persons coming into contact with the equipment;
-
installation safeguards are useful when a safety characteristic can only be provided after installation (for example, the equipment shall be bolted to the floor to provide stability);
-
behavioural safeguards are useful when the equipment requires an energy source to be accessible.
In practice, safeguard selection accounts for the nature of the energy source, the intended user, the functional requirements of the equipment, and similar considerations.

0.5.2Equipment safeguard

0.5.3Installation safeguard

Installation safeguards are not controlled by the equipment manufacturer, although in some cases, installation safeguards may be specified in the equipment installation instructions.
Generally, with respect to equipment, an installation safeguard is a supplementary safeguard.
NOTEFor example, the supplementary safeguard providing protective earthing is located partly in the equipment and partly in the installation. The supplementary safeguard providing protective earthing is not effective until the equipment is connected to the protective earthing of the installation.
Requirements for installation safeguards are not addressed in this document. However, this document does assume some installation safeguards, such as protective earthing, are in place and are effective.

0.5.4Personal safeguard

Requirements for personal safeguards are not addressed in this document. However, this document does assume that personal safeguards are available for use as specified by the manufacturer.

0.5.5Behavioural safeguards

0.5.5.1Introduction to behavioural safeguards
In the absence of an equipment, installation, or personal safeguard, a person can use a specific behaviour as a safeguard to avoid energy transfer and consequent injury. A behavioural safeguard is a voluntary or instructed behaviour intended to reduce the likelihood of transfer of energy to a body part.
Three kinds of behavioural safeguards are specified in this document. Each kind of behavioural safeguard is associated with a specific kind of person. An instructional safeguard is usually addressed to an ordinary person, but can also be addressed to an instructed person or a skilled person. A precautionary safeguard is used by an instructed person. A skill safeguard is used by a skilled person.
As an equipment safeguard provides protection for all persons, it is preferred above a behavioural safeguard. However, in certain situations a precautionary safeguard or a skill safeguard is accepted as a replacement of an equipment safeguard.
0.5.5.2Instructional safeguard
An instructional safeguard is a means of providing information, describing the existence and location of an energy source capable of causing pain or injury, and is intended to invoke a specific behaviour on the part of a person to reduce the likelihood of transfer of energy to a body part (see Annex F).
An instructional safeguard may be a visual indicator (symbols or words or both) or an audible message, as applicable to the expected use of the product.
When accessing locations where the equipment needs to be energized to perform a service activity, an instructional safeguard can be considered acceptable protection to bypass an equipment safeguard such that the person is made aware of how to avoid contact with a class 2 or class 3 energy source.
If equipment safeguards would interfere with or prohibit the equipment function, an instructional safeguard may replace an equipment safeguard.
If exposure to an energy source capable of causing pain or injury is essential to the correct functioning of equipment, an instructional safeguard may be used to ensure protection of persons instead of another safeguard. Consideration should be given as to whether the instructional safeguard should use a personal safeguard.
Provision of an instructional safeguard does not result in an ordinary person becoming an instructed person (see 0.5.5.3).
0.5.5.3Precautionary safeguard (used by an instructed person)
A precautionary safeguard is the training and experience or supervision of an instructed person by a skilled person to use precautions to protect the instructed person against class 2 energy sources. Precautionary safeguards are not specifically prescribed in this document but are assumed to be effective when the term instructed person is used.
During equipment servicing, it is possible that an instructed person will need to remove or defeat an equipment safeguard. In this case, an instructed person is expected to then apply precaution as a safeguard to avoid exposure to class 2 energy sources.
0.5.5.4Skill safeguard (used by a skilled person)
A skill safeguard is the education, training, knowledge and experience of the skilled person that is used to protect the skilled person against class 2 or class 3 energy sources. Skill safeguards are not specifically prescribed in this document but are assumed to be effective when the term skilled person is used.
During equipment servicing, it is possible that a skilled person will need to remove or defeat an equipment safeguard. In this case, a skilled person is expected to then apply skill as a safeguard to avoid injury.

0.5.6Safeguards during ordinary or instructed person service conditions

During ordinary person or instructed person service conditions, safeguards for such persons can be applicable. Such safeguards may be equipment safeguards, personal safeguards, or instructional safeguards.

0.5.7Equipment safeguards during skilled person service conditions

During skilled person service conditions, equipment safeguards should be provided to protect against the effects of a body's involuntary reaction (for example, startle) that might cause unintentional contact with a class 3 energy source located outside the view of the skilled person.
NOTEThis safeguard typically applies in large equipment, where the skilled person needs to partially or wholly enter between two or more class 3 energy source locations while servicing.

0.5.8Examples of safeguard characteristics

Table 3 lists some examples of safeguard characteristics.
Table 3 — Examples of safeguard characteristics
Safeguard Basic safeguard Supplementary safeguard Reinforced safeguard
Equipment safeguard:
a physical part of an equipment
Effective under normal operating conditions Effective in the event of failure of the basic safeguard Effective under normal operating conditions and in the event of a single fault condition elsewhere in the equipment
Example:normal temperatures below ignition temperatures
Not applicable
Installation safeguard:
a physical part of a man-made installation
Effective under normal operating conditions Effective in the event of failure of an equipment basic safeguard Effective under normal operating conditions and in the event of a single fault condition elsewhere in the equipment
Example:wire size
Example:overcurrent protective device
Example:socket-outlet
Personal safeguard:
a physical device worn on the body
In the absence of any equipment safeguard, effective under normal operating conditions Effective in the event of failure of an equipment basic safeguard In the absence of any equipment safeguard, effective under normal operating conditions and in the event of a single fault condition elsewhere in the equipment
Example:gloves
Example:insulating floor mat
Example:electrically-insulated glove for handling live conductors
Instructional safeguard:
a voluntary or instructed behaviour intended to reduce the likelihood of transfer of energy to a body part
In the absence of any equipment safeguard, effective under normal operating conditions Effective in the event of failure of an equipment basic safeguard Only effective on an exceptional basis, when providing all appropriate safeguards would prevent the intended functioning of the equipment
Example:instructional safeguard to disconnect telecommunication cable before opening the cover
Example:after opening a door, an instructional safeguard against hot parts
Example:instructional safeguard of hot parts in an office photocopier, or a continuous roll paper cutter on a commercial printer

0.6Electrically-caused pain or injury (electric shock)

0.6.1Models for electrically-caused pain or injury

Electrically-caused pain or injury can occur when electrical energy capable of causing pain or injury is transferred to a body part (see Figure 3).
Electrical energy transfer occurs when there are two or more electrical contacts to the body:
-
the first electrical contact is between a body part and a conductive part of the equipment;
-
the second electrical contact is between another body part and
•
earth, or
•
another conductive part of the equipment.
Figure 3 — Schematic and model for electrically-caused pain or injury
graphic
Depending on the magnitude, duration, wave shape, and frequency of the current, the effect on the human body varies from undetectable to detectable to painful to injurious.

0.6.2Models for protection against electrically-caused pain or injury

One or more safeguards are interposed between an electrical energy source capable of causing pain or injury and a body part to protect against electrically-caused pain or injury (see Figure 4).
Figure 4 — Model for protection against electrically-caused pain or injury
graphic
Protection against electrically-caused pain is provided under normal operating conditions and abnormal operating conditions. For such protection, under normal operating conditions and abnormal operating conditions, a basic safeguard is interposed between an electrical energy source capable of causing pain and an ordinary person.
The most common basic safeguard against an electrical energy source capable of causing pain is electrical insulation (also known as basic insulation) interposed between the energy source and a body part.
Protection against electrically-caused injury is provided under normal operating conditions, abnormal operating conditions, and single fault conditions. For such protection, under normal operating conditions and abnormal operating conditions, both a basic safeguard and a supplementary safeguard are interposed between an electrical energy source capable of causing injury and an ordinary person (see 4.3.2.4), or an instructed person (see 4.3.3.3). In the event of a failure of either safeguard, the other safeguard becomes effective. The supplementary safeguard against an electrical energy source capable of causing injury is placed between the basic safeguard and a body part. A supplementary safeguard may be additional electrical insulation (supplementary insulation) or a protectively earthed conductive barrier or other construction that performs the same function.
Another safeguard against an electrical energy source capable of causing injury is electrical insulation (also known as double insulation or reinforced insulation) placed between the energy source and a body part.
Likewise, a reinforced safeguard may be placed between an electrical energy source capable of causing injury and a body part.

0.7Electrically-caused fire

0.7.1Models for electrically-caused fire

Electrically-caused fire is due to conversion of electrical energy to thermal energy (see Figure 5), where the thermal energy heats a fuel material followed by ignition and combustion.
Figure 5 — Model for electrically-caused fire
graphic
Electrical energy is converted to thermal energy either in a resistance or in an arc and is transferred to a fuel material by conduction, convection, or radiation. As the fuel material heats, it chemically decomposes into gases, liquids and solids. When the gas is at its ignition temperature, the gas can be ignited by an ignition source. When the gas is at its spontaneous ignition temperature, the gas ignites by itself. Both result in fire.

0.7.2Models for protection against electrically-caused fire

The basic safeguard against electrically-caused fire (see Figure 6) is that the temperature of a material, under normal operating conditions and abnormal operating conditions, does not cause the material to ignite.
The supplementary safeguard against electrically-caused fire reduces the likelihood of ignition or, in the case of ignition, reduces the likelihood of spread of fire.
Figure 6 — Models for protection against fire
graphic

0.8Injury caused by hazardous substances

Injury caused by hazardous substances is due to a chemical reaction with a body part. The extent of injury by a given substance depends on both the magnitude and duration of exposure and on the body part susceptibility to that substance.
The basic safeguard against injury caused by hazardous substances is containment of the material.
Supplementary safeguards against injury caused by hazardous substances may include:
-
a second container or a spill-resistant container;
-
containment trays;
-
tamper-proof screws to prevent unauthorized access;
-
instructional safeguards.
National and regional regulations govern the use of and exposure to hazardous substances used in equipment. These regulations do not enable a practical classification of hazardous substances in the manner in which other energy sources are classified in this document. Therefore, energy source classifications are not applied in Clause 7.

0.9Mechanically-caused injury

Mechanically-caused injury is due to kinetic energy transfer to a body part when a collision occurs between a body part and an equipment part. The kinetic energy is a function of the relative motion between a body part and accessible parts of the equipment, including parts ejected from the equipment that collide with a body part.
Examples of kinetic energy sources are:
-
body motion relative to sharp edges and corners;
-
part motion due to rotating or other moving parts, including pinch points;
-
part motion due to loosening, exploding, or imploding parts;
-
equipment motion due to instability;
-
equipment motion due to wall, ceiling, or rack mounting means failure;
-
equipment motion due to handle failure;
-
part motion due to an exploding battery;
-
equipment motion due to cart or stand instability or failure.
The basic safeguard against mechanically-caused injury is a function of the specific energy source. Basic safeguards may include:
-
rounded edges and corners;
-
an enclosure to prevent a moving part from being accessible;
-
an enclosure to prevent expelling a moving part;
-
a safety interlock to control access to an otherwise moving part;
-
means to stop the motion of a moving part;
-
means to stabilize the equipment;
-
robust handles;
-
robust mounting means;
-
means to contain parts expelled during explosion or implosion.
The supplementary safeguard against mechanically-caused injury is a function of the specific energy source. Supplementary safeguards may include:
-
instructional safeguards;
-
instructions and trainings;
-
additional enclosures or barriers;
-
safety interlocks.
The reinforced safeguard against mechanically-caused injury is a function of the specific energy source. Reinforced safeguards may include:
-
extra thick glass on the front of a CRT;
-
rack slide-rails and means of support;

0.10Thermally-caused injury (skin burn)

0.10.1Models for thermally-caused injury

Thermally-caused injury can occur when thermal energy capable of causing injury is transferred to a body part (see Figure 7).
Thermal energy transfer occurs when a body touches a hot equipment part. The extent of injury depends on the temperature difference, the thermal mass of the object, rate of thermal energy transfer to the skin, and duration of contact.
Figure 7 — Schematic and model for thermally-caused injury
graphic
Depending on the temperature, contact duration, material properties, and mass of the material, the perception of the human body varies from warmth to heat that can result in pain or injury (burn).

0.10.2Models for protection against thermally-caused pain or injury

One or more safeguards are interposed between a thermal energy source capable of causing pain or injury and an ordinary person (see Figure 8).
Figure 8 — Model for protection against thermally-caused injury
graphic
Under normal operating conditions and abnormal operating conditions, protection is used against thermally-cause pain. For such protection, a basic safeguard is interposed between a thermal energy source capable of causing pain and an ordinary person.
Under normal operating conditions, abnormal operating conditions and single fault conditions, protection is used against thermally-caused injury. For such protection, a basic safeguard and a supplementary safeguard are interposed between a thermal energy source capable of causing injury and an ordinary person.
The basic safeguard against a thermal energy source capable of causing pain or injury is thermal insulation placed between the energy source and a body part. In some cases, a basic safeguard against a thermal energy source capable of causing pain or injury can be an instructional safeguard identifying the hot parts and how to reduce the likelihood of injury. In some cases, a basic safeguard reduces the likelihood of a non-injurious thermal energy source from becoming a thermal energy source capable of causing pain or injury.
Examples of such basic safeguards are:
-
control of electrical energy being converted to thermal energy (for example, a thermostat);
-
heat sinking, etc.
The supplementary safeguard against a thermal energy source capable of causing injury is thermal insulation placed between the energy source and a body part. In some cases, a supplementary safeguard against a thermal energy source capable of causing pain or injury can be an instructional safeguard identifying the hot parts and how to reduce the likelihood of injury.

0.11Radiation-caused injury

Radiation-caused injury within the scope of this document is generally attributed to one of the following energy transfer mechanisms:
-
heating of a body organ caused by exposure to non-ionising radiation, such as the highly localised energy of a laser impinging on the retina; or
-
auditory injury caused by over stimulation of the ear by excessive peaks or sustained loud sound, leading to physical or nerve damage; or
-
X-radiation; or
-
UV radiation.
Radiated energy is transferred by impingement of wave emission upon a body part.
The basic safeguard against radiation-caused injury is containment of the energy within an enclosure that is opaque to the radiated energy.
There are several supplementary safeguards against radiation-caused injury. The supplementary safeguards can include safety interlocks to disconnect power to the generator, tamper-proof screws to prevent unauthorized access, etc.
The basic safeguard against auditory injury is to limit the acoustic output level of personal music players and their associated headphones and earphones.
Examples of supplementary safeguards against auditory pain and injury are the provision of warnings and information advising the user how to use the equipment correctly.
30mm
20mm
15mm
15mm
10mm
17mm

Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
GSO IEC 62368-1:2024Gulf Standard
International StandardIEC 62368-1:2023 ED4
Audio/video, information and communication technology equipment - Part 1: Safety requirements

1Scope

This part of IEC 62368 is applicable to the safety of electrical and electronic equipment within the field of audio, video, information and communication technology, and business and office machines with a rated voltage not exceeding 600 V. This document does not include requirements for performance or functional characteristics of equipment.
NOTE 1Examples of equipment within the scope of this document are given in Annex A.
NOTE 2A rated voltage of 600 V is considered to include equipment rated 400/690 V.
Explanatory information related to this document is contained in IEC TR 62368-2. It provides rationale together with explanatory information that can be helpful to apply to this document.
This document is also applicable to:
-
components and subassemblies intended for incorporation in this equipment. Such components and subassemblies need not comply with every requirement of this document, provided that the complete equipment, incorporating such components and subassemblies, does comply;
-
external power supply units intended to primarily supply equipment within the scope of this document;
-
accessories intended to be used with equipment within the scope of this document;
-
large equipment installed in restricted access areas. For equipment having large machinery aspects, additional requirements can apply; and
-
equipment to be used in tropical regions.
This document also includes requirements for audio/video, information and communication technology equipment intended to be installed in an outdoor location. The requirements for outdoor equipment also apply, where relevant, to outdoor enclosures suitable for direct installation in the field and supplied for housing audio/video, information and communication technology equipment to be installed in an outdoor location. See Annex Y for specific construction requirements not covered elsewhere in this document.
This document harmonizes with IEC 61140 and gives consideration to the electrical installation by properly interfacing with the common safety aspects of the installation.
Each installation can have particular requirements. In addition, requirements for protection of the outdoor equipment against the effects of direct lightning strikes are not covered by this document.
NOTE 3For information on this subject, see IEC 62305-1.
This document assumes a maximum altitude of 2 000 m unless otherwise specified by the manufacturer.
Additional requirements for equipment having the capability to supply or receive DC power over commonly used communication cables, such as USB or Ethernet (PoE), are given in IEC 62368-3. IEC 62368-3 does not apply to:
-
equipment supplying or receiving power using proprietary connectors; or
-
equipment using a proprietary protocol to enable the power transfer.
This document specifies safeguards for ordinary persons, instructed persons, and skilled persons. Additional requirements can apply for equipment that is clearly designed or intended for use by children or specifically attractive to children.
NOTE 4In Australia, the work conducted by an instructed person or a skilled person can require formal licensing from regulatory authorities.
NOTE 5In Germany, in many cases a person can only be regarded as an instructed person or a skilled person if certain legal requirements are fulfilled.
This document does not apply to:
-
equipment with non-self-contained hazardous moving parts, such as robotic equipment;
NOTE 6For requirements related to robotic equipment in an industrial environment, see IEC 60204-1, IEC 60204-11, ISO 10218-1 and ISO 10218-2.
-
personal care robots, including mobile servant robots, physical assistant robots, and person carrier robots;
NOTE 7For requirements related to personal care robots, see ISO 13482.
-
power supply systems that are not an integral part of the equipment, such as motor-generator sets, battery backup systems and distribution transformers;
-
equipment to be used in wet areas indoors.
This document does not address:
-
manufacturing processes except for routine tests;
-
injurious effects of gases released by thermal decomposition or combustion;
-
disposal processes;
-
effects of transport (other than as specified in this document);
-
effects of storage of materials, components, or the equipment itself;
-
the likelihood of injury from particulate radiation such as alpha particles and beta particles;
-
the use of the equipment in oxygen-enriched or explosive atmospheres;
-
exposure to chemicals other than as specified in Clause 7;
-
electrostatic discharge events;
-
exposure to electromagnetic fields;
-
environmental aspects; or
-
requirements for functional safety, except for those related to work cells.
NOTE 8For specific functional and software safety requirements of electronic safety-related systems (for example, protective electronic circuits), see IEC 61508-1.

2Normative references

The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60027-1, Letter symbols to be used in electrical technology - Part 1: General
IEC 60038, IEC standard voltages
IEC 60068-2-6, Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-11, Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-78, Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 60073, Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators
IEC TR 60083, Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC
IEC 60085, Electrical insulation - Thermal evaluation and designation
IEC 60086-4, Primary batteries - Part 4: Safety of lithium batteries
IEC 60086-5, Primary batteries - Part 5: Safety of batteries with aqueous electrolyte
IEC 60107-1:1997, Methods of measurement on receivers for television broadcast transmissions - Part 1: General considerations - Measurements at radio and video frequencies
IEC 60112, Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 60127 (all parts), Miniature fuses
IEC 60127-8, Miniature fuses - Part 8: Fuse resistors with particular overcurrent protection
IEC 60227-1, Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements
IEC 60227-2:1997, 1 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 2: Test methods
IEC 60227-2:1997/AMD1:2003
IEC 60243-1, Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies
IEC 60245-1, Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 1: General requirements
IEC 60268-1:1985, Sound system equipment - Part 1: General
IEC 60268-1:1985/AMD1:1988
IEC 60268-1:1985/AMD2:1988
IEC 60309 (all parts), Plugs, socket-outlets and couplers for industrial purposes
IEC 60317 (all parts), Specifications for particular types of winding wires
IEC 60317-0-7:2017, Specifications for particular types of winding wires - Part 0-7: General requirements - Fully insulated (FIW) zero-defect enamelled round copper wire
IEC 60317-43, Specifications for particular types of winding wires - Part 43: Aromatic polyimide tape wrapped round copper wire, class 240
IEC 60317-56, Specifications for particular types of winding wires - Part 56: Solderable fully insulated (FIW) zero-defect polyurethane enamelled round copper wire, class 180
IEC 60320 (all parts), Appliance couplers for household and similar general purposes
IEC 60320-1, Appliance couplers for household and similar general purposes - Part 1: General requirements
IEC 60332-1-2, Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
IEC 60332-1-3, Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
IEC 60332-2-2, Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame
IEC 60384-14:2013, Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
IEC 60384-14:2013/AMD1:2016
IEC 60417 Graphical symbols for use on equipment, available at http://www.graphical-symbols.info/equipment
IEC 60529:1989, Degrees of protection provided by enclosures (IP Code)
IEC 60529:1989/AMD1:1999
IEC 60529:1989/AMD2:2013
IEC 60664-1:2020, Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60664-3, Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
IEC 60691:2015, Thermal-links - Requirements and application guide
IEC 60695-2-11, Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
IEC 60695-10-2, Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method
IEC 60695-10-3, Fire hazard testing - Part 10-3: Abnormal heat - Mould stress relief distortion test
IEC 60695-11-5:2016, Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
IEC 60695-11-10, Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
IEC 60695-11-20:2015, Fire hazard testing - Part 11-20: Test flames - 500 W flame test methods
IEC TS 60695-11-21, Fire hazard testing - Part 11-21: Test flames - 500 W vertical flame test method for tubular polymeric materials
IEC 60728-11:2016, Cable networks for television signals, sound signals and interactive services - Part 11: Safety
IEC 60730 (all parts), Automatic electrical controls for household and similar use
IEC 60730-1:2022, Automatic electrical controls - Part 1: General requirements
IEC 60738-1:2022, Thermistors - Directly heated positive temperature coefficient - Part 1: Generic specification
IEC 60747-5-5:2020, Semiconductor devices - Part 5-5: Optoelectronic devices - Photocouplers
IEC 60825-1:2014, Safety of laser products - Part 1: Equipment classification and requirements
IEC 60825-2, Safety of laser products - Part 2: Safety of optical fibre communication systems (OFCSs)
IEC 60825-12, Safety of laser products - Part 12: Safety of free space optical communication systems used for transmission of information
IEC 60851-3:2009, Winding wires - Test methods - Part 3: Mechanical properties
IEC 60851-3:2009/AMD1:2013
IEC 60851-3:2009/AMD2:2019
IEC 60851-5:2008, Winding wires - Test methods - Part 5: Electrical properties
IEC 60851-5:2008/AMD1:2011
IEC 60851-5:2008/AMD2:2019
IEC 60884-1, Plugs and socket-outlets for household and similar purposes - Part 1: General requirements
IEC 60896-11, Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests
IEC 60896-21:2004, Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test
IEC 60896-22, Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements
IEC 60906-1, IEC system of plugs and socket-outlets for household and similar purposes - Part 1: Plugs and socket-outlets 16 A 250 V a.c.
IEC 60906-2, IEC system of plugs and socket-outlets for household and similar purposes - Part 2: Plugs and socket-outlets 15 A 125 V a.c. and 20 A 125 V a.c.
IEC 60947-1, Low-voltage switchgear and controlgear - Part 1: General rules
IEC 60947-5-5, Low-voltage switchgear and controlgear - Part 5-5: Control circuit devices and switching elements - Electrical emergency stop device with mechanical latching function
IEC 60990:2016, Methods of measurement of touch current and protective conductor current
IEC 60998-1, Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General requirements
IEC 60999-1, Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included)
IEC 60999-2, Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included)
IEC 61051-1, Varistors for use in electronic equipment - Part 1: Generic specification
IEC 61051-2:2021, Varistors for use in electronic equipment - Part 2: Sectional specification for surge suppression varistors
IEC 61056-1, General purpose lead-acid batteries (valve-regulated types) - Part 1: General requirements, functional characteristics - Methods of test
IEC 61056-2, General purpose lead-acid batteries (valve-regulated types) - Part 2: Dimensions, terminals and marking
IEC 61058-1:2016, Switches for appliances - Part 1: General requirements
IEC 61204-7, Low-voltage switch mode power supplies - Part 7: Safety requirements
IEC 61260-1:2014, Electroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications
IEC 61293, Marking of electrical equipment with ratings related to electrical supply - Safety requirements
IEC 61427 (all parts), Secondary cells and batteries for renewable energy storage - General requirements and methods of test
IEC TS 61430, Secondary cells and batteries - Test methods for checking the performance of devices designed for reducing explosion hazards - Lead-acid starter batteries
IEC 61434, Secondary cells and batteries containing alkaline or other non-acid electrolytes - Guide to designation of current in alkaline secondary cell and battery standards
IEC 61558-1:2017, Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests
IEC 61558-2-16, Safety of transformers, reactors, power supply units and combinations thereof - Part 2-16: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units for general applications
IEC 61587-1:2022, Mechanical structures for electrical and electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test setups and safety aspects
IEC 61643-11:2011, Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
IEC 61643-331:2020, Components for low-voltage surge protection - Part 331: Performance requirements and test methods for metal oxide varistors (MOV)
IEC 61810-1:2015, Electromechanical elementary relays - Part 1: General and safety requirements
IEC 61810-1:2015/AMD1:2019
IEC 61959, Secondary cells and batteries containing alkaline or other non-acid electrolytes - Mechanical tests for sealed portable secondary cells and batteries
IEC 61965:2003, Mechanical safety of cathode ray tubes
IEC 61984, Connectors - Safety requirements and tests
IEC 62061, Safety of machinery - Functional safety of safety-related control systems
IEC 62133-1, Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 1: Nickel systems
IEC 62133-2:2017, Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems
IEC 62133-2:2017/AMD1:2021
IEC 62230, Electric cables - Spark-test method
IEC 62281, Safety of primary and secondary lithium cells and batteries during transport
IEC 62440:2008, Electric cables with a rated voltage not exceeding 450/750 V - Guide to use
IEC 62471:2006, Photobiological safety of lamps and lamp systems
IEC 62471-5:2015, Photobiological safety of lamps and lamp systems - Part 5: Image projectors
IEC 62485-2, Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries
IEC 62619:2022, Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications
IEC 62821-1, Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 1: General requirements
IEC 62821-2, 2 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 2: Test methods
IEC 62821-3, Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 3: Flexible cables (cords)
IEC 63010-1, Halogen-free thermoplastic insulated and sheathed flexible cables of rated voltages up to and including 300/300 V - Part 1: General requirements and cables
IEC 63010-2, 3 Halogen-free thermoplastic insulated and sheathed flexible cables of rated voltages up to and including 300/300 V - Part 2: Test methods
IEC 63294:2021, Test methods for electric cables with rated voltages up to and including 450/750 V
ISO 37, Rubber, vulcanized or thermoplastic - Determination of tensile stress-strain properties
ISO 178, Plastics - Determination of flexural properties
ISO 179-1, Plastics - Determination of Charpy impact properties - Part 1: Non-instrumented impact test
ISO 180, Plastics - Determination of Izod impact strength
ISO 306, Plastics - Thermoplastic materials - Determination of Vicat softening temperature (VST)
ISO 527 (all parts), Plastics - Determination of tensile properties
ISO 871, Plastics - Determination of ignition temperature using a hot-air furnace
ISO 1798, Flexible cellular polymeric materials - Determination of tensile strength and elongation at break
ISO 1817:2022, Rubber, vulcanized or thermoplastic - Determination of the effect of liquids
ISO 2719, Determination of flash point - Pensky-Martens closed cup method
ISO 3679, Determination of flash point - Method for flash no-flash and flash point by small scale closed cup tester
ISO 3864 (all parts), Graphical symbols - Safety colours and safety signs
ISO 3864-2, Graphical symbols - Safety colours and safety signs - Part 2: Design principles for product safety labels
ISO 4892-1, Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance
ISO 4892-2:2013, Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps
ISO 4892-4, Plastics - Methods of exposure to laboratory light sources - Part 4: Open-flame carbon-arc lamps
ISO 7000 Graphical symbols for use on equipment - Registered symbols, available at http://www.graphical-symbols.info/equipment
ISO 7010, Graphical symbols - Safety colours and safety signs - Registered safety signs
ISO 8256, Plastics - Determination of tensile-impact strength
ISO 9772, Cellular plastics - Determination of horizontal burning characteristics of small specimens subjected to a small flame
ISO 9773, Plastics - Determination of burning behaviour of thin flexible vertical specimens in contact with a small-flame ignition source
ISO 13849-1, Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design
ISO 14993, Corrosion of metals and alloys - Accelerated testing involving cyclic exposure to salt mist, "dry" and "wet" conditions
ISO 21207, Corrosion tests in artificial atmospheres - Accelerated corrosion tests involving alternate exposure to corrosion-promoting gases, neutral salt-spray and drying
ISO 22479, Corrosion of metals and alloys - Sulfur dioxide test in a humid atmosphere (fixed gas method)
ASTM D412, Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers - Tension
ASTM D471-98, Standard Test Method for Rubber Property - Effect of Liquids
ASTM D3574, Standard Test Methods for Flexible Cellular Materials - Slab, Bonded, and Molded Urethane Foams
EN 50332-1:2013, Sound system equipment: Headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 1: General method for "one package equipment"
EN 50332-2 Sound system equipment: Headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 2: Matching of sets with headphones if either or both are offered separately, or are offered as one package equipment but with standardised connectors between the two allowing to combine components of different manufacturers or different design
EN 50332-3:2017, Sound system equipment: Headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 3: Measurement method for sound dose management

3Terms, definitions and abbreviated terms

3.1Energy source abbreviated terms

Abbreviation Description
ES Electrical energy source see 5.2
ES1 Electrical energy source class 1
ES2 Electrical energy source class 2
ES3 Electrical energy source class 3
MS Mechanical energy source see 8.2
MS1 Mechanical energy source class 1
MS2 Mechanical energy source class 2
MS3 Mechanical energy source class 3
PS Power source see 6.2
PS1 Power source class 1
PS2 Power source class 2
PS3 Power source class 3
RS Radiation energy source see 10.2
RS1 Radiation energy source class 1
RS2 Radiation energy source class 2
RS3 Radiation energy source class 3
TS Thermal energy source see 9.2
TS1 Thermal energy source class 1
TS2 Thermal energy source class 2
TS3 Thermal energy source class 3

3.2Other abbreviated terms

Abbreviation Description
AIT auto ignition temperature
AWG American wire gauge
CD compact disc
CD ROM compact disc read-only memory
CRT cathode ray tube
CSD calculated sound dose
CTI comparative tracking index
dBFS digital signal level relative to full scale
DVD digital versatile disc
E sound exposure
EIS electrical insulation system
EUT equipment under test
FIW fully insulated winding wire
GDT gas discharge tube
IC integrated circuit
ICX integrated circuit with X-capacitor function
IR infrared
LED light emitting diode
LEL lower explosion limit
LFL lower flammability limit
LFC liquid filled component
LPS limited power source
MEL momentary exposure level
MOV metal oxide varistor
NEMA National Electrical Manufacturers Association
NiCd nickel cadmium
PIS potential ignition source
PMP personal music player
PoE power over Ethernet
PPE personal protective equipment
PTC positive temperature coefficient
PTI proof tracking index
RC resistor-capacitor
RG risk group
Sb antimony
SEL sound exposure level
SRME slide rail mounted equipment
TSS thyristor surge suppressor
UPS uninterruptible power supply
USB universal serial bus
UV ultraviolet
VDR voltage dependent resistor
VRLA valve regulated lead acid

3.3Terms and definitions

For the purposes of this document the following terms and definitions apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
•
IEC Electropedia: available at http://www.electropedia.org/
•
ISO Online browsing platform: available at http://www.iso.org/obp
For the convenience of the user, the defined terms are listed below in alphabetical order indicating the number of the defined term.
Where the words "voltage" and "current" or their abbreviations are used, they are RMS values unless otherwise specified in this document.
5VA class material 3.3.4.2.1
5VB class material 3.3.4.2.2
abnormal operating condition 3.3.7.1
accessible 3.3.6.1
audio amplifier 3.3.1.1
arcing PIS 3.3.9.2
backfeed 3.3.6.2
backfeed safeguard 3.3.11.1
basic insulation 3.3.5.1
basic safeguard 3.3.11.2
battery 3.3.17.1
button cell battery 3.3.17.3
calculated sound dose, CSD 3.3.19.1
cell 3.3.17.2
cheesecloth 3.3.6.3
class I equipment 3.3.15.1
class II construction 3.3.15.2
class II equipment 3.3.15.3
class III equipment 3.3.15.4
clearance 3.3.12.1
coin cell battery 3.3.17.3
combustible material 3.3.4.1
consumable material 3.3.16.1
coolant 3.3.6.4
creepage distance 3.3.12.2
DC voltage 3.3.14.1
device 3.3.6.5
digital signal level relative to full scale, dBFS 3.3.19.5
direct plug-in equipment 3.3.3.1
disconnect device 3.3.6.6
double insulation 3.3.5.2
double safeguard 3.3.11.3
electrical enclosure 3.3.2.1
enclosure 3.3.2.2
equipment safeguard 3.3.11.4
explosion 3.3.16.2
explosive 3.3.16.3
external circuit 3.3.1.2
fire enclosure 3.3.2.3
fixed equipment 3.3.3.2
fully insulated winding wire, FIW 3.3.18.1
functional earthing 3.3.6.7
functional insulation 3.3.5.3
grade of FIW 3.3.18.2
hand-held equipment 3.3.3.3
hazardous substance 3.3.16.4
HB40 class material 3.3.4.2.3
HB75 class material 3.3.4.2.4
HBF class foamed material 3.3.4.2.5
HF-1 class foamed material 3.3.4.2.6
HF-2 class foamed material 3.3.4.2.7
highest specified charging temperature 3.3.17.4
installation safeguard 3.3.11.5
instructed person 3.3.8.1
instructional safeguard 3.3.11.6
insulating liquid 3.3.5.4
intermittent operation 3.3.7.2
liquid cooling system 3.3.6.8
liquid filled component, LFC 3.3.6.9
liquid filled component assembly, LFC assembly 3.3.6.10
loudspeaker driver 3.3.6.11
lowest specified charging temperature 3.3.17.5
mains 3.3.1.3
mains transient voltage 3.3.14.2
material flammability class 3.3.4.2
maximum specified charging current 3.3.17.6
maximum specified charging voltage 3.3.17.7
mechanical enclosure 3.3.2.4
modular liquid filled component, modular LFC 3.3.6.12
momentary exposure level, MEL 3.3.19.2
movable equipment 3.3.3.4
non-clipped output power 3.3.7.3
non-detachable power supply cord 3.3.6.13
normal operating condition 3.3.7.4
ordinary person 3.3.8.2
outdoor enclosure 3.3.2.5
outdoor equipment 3.3.3.5
outdoor location 3.3.6.14
peak response frequency 3.3.7.5
permanently connected equipment 3.3.3.6
personal safeguard 3.3.11.7
pink noise 3.3.1.4
pluggable, type A equipment 3.3.3.7
pluggable, type B equipment 3.3.3.8
pollution degree 3.3.6.15
potential ignition source, PIS 3.3.9.1
precautionary safeguard 3.3.11.8
professional equipment 3.3.3.9
prospective touch voltage 3.3.14.3
protective bonding conductor 3.3.11.9
protective conductor current 3.3.14.4
protective conductor 3.3.11.10
protective current rating 3.3.10.6
protective earthing 3.3.11.11
protective earthing conductor 3.3.11.12
rated current 3.3.10.1
rated frequency 3.3.10.2
rated load impedance 3.3.7.6
rated power 3.3.10.3
rated voltage range 3.3.10.5
rated voltage 3.3.10.4
reasonably foreseeable misuse 3.3.7.7
reinforced insulation 3.3.5.5
reinforced safeguard 3.3.11.13
required withstand voltage 3.3.14.5
resistive PIS 3.3.9.3
restricted access area 3.3.6.16
RMS working voltage 3.3.14.6
routine test 3.3.6.17
safeguard 3.3.11.14
safety interlock 3.3.11.15
sampling test 3.3.6.18
secondary lithium battery 3.3.17.8
self-contained LFC 3.3.6.19
short-time operation 3.3.7.8
single fault condition 3.3.7.9
skill safeguard 3.3.11.16
skilled person 3.3.8.3
solid insulation 3.3.5.6
sound exposure, E 3.3.19.3
sound exposure level, SEL 3.3.19.4
stationary equipment 3.3.3.10
stored energy mode 3.3.6.20
subassembly 3.3.6.21
supplementary insulation 3.3.5.7
supplementary safeguard 3.3.11.17
temperature limiter 3.3.13.1
temporary overvoltage 3.3.14.7
thermal cut-off 3.3.13.2
thermostat 3.3.13.3
tool 3.3.6.22
touch current 3.3.6.23
transportable equipment 3.3.3.11
type test 3.3.6.24
V-0 class material 3.3.4.2.8
V-1 class material 3.3.4.2.9
V-2 class material 3.3.4.2.10
VTM-0 class material 3.3.4.2.11
VTM-1 class material 3.3.4.2.12
VTM-2 class material 3.3.4.2.13
wireless power transmitter 3.3.3.12
work cell 3.3.6.25
working voltage 3.3.14.8
wrapping tissue 3.3.6.26

3.3.1Circuit terms

3.3.1.1
audio amplifier
amplifying device for audio signals intended to drive loudspeakers and headphones
3.3.1.2
external circuit
electrical circuit that is external to the equipment and is not mains
Note 1 to entry: An external circuit is classified as ES1, ES2 or ES3, and PS1, PS2, or PS3.
3.3.1.3
mains
AC or DC power distribution system (external to the equipment) that supplies operating power to the equipment
Note 1 to entry: Mains include public or private utilities and, unless otherwise specified in this document, equivalent sources such as motor-driven generators and uninterruptible power supplies.
Note 2 to entry: Powering external circuits by using communications cables and circuits that are isolated from the mains (for example, data, voice, PoE, USB, HDMI, Coaxial, RFT and similar circuits in Table 13) are not considered to be mains.
3.3.1.4
pink noise
stationary random signal having normal probability distribution of instantaneous values whose energy per unit bandwidth (ΔW/Δf) is inversely proportional to frequency
Note 1 to entry: Unless otherwise stated, the mean value is zero.
Note 2 to entry: See E.2.1

3.3.2Enclosure terms

3.3.2.1
electrical enclosure
enclosure intended as a safeguard against electrically-caused injury
[SOURCE: IEC 60050-195:2021, 195-06-13, modified - the term safeguard has been used]
3.3.2.2
enclosure
housing affording the type and degree of protection suitable for the intended application
[SOURCE: IEC 60050-195:2021, 195-02-35]
3.3.2.3
fire enclosure
enclosure intended as a safeguard against the spread of fire from within the enclosure to outside the enclosure
3.3.2.4
mechanical enclosure
enclosure intended as a safeguard against mechanically-caused pain and injury
3.3.2.5
outdoor enclosure
enclosure that is intended to provide protection from specific conditions in an outdoor location
Note 1 to entry: An outdoor enclosure may also perform the functions of another enclosure, for example: a fire enclosure; an electrical enclosure; a mechanical enclosure.
Note 2 to entry: A separate cabinet or housing into which the equipment is placed may provide the function of an outdoor enclosure.

3.3.3Equipment terms

3.3.3.1
direct plug-in equipment
equipment in which the mains plug forms an integral part of the equipment enclosure
3.3.3.2
fixed equipment
equipment fastened to a support, or otherwise secured in a specific location by a means defined by the manufacturer in the installation instructions.
Note 1 to entry: Equipment that has a screw hole or other means to secure the equipment by an ordinary person, such as for securement to a table or for earthquake protection, is not considered to be fixed equipment.
Note 2 to entry: Typically, fixed equipment will be wall, ceiling or floor mounted.
[SOURCE: IEC 60050-826:2022, 826-16-07, modified ─ Addition of the requirement for defining the means in the installation instructions, and addition of notes to entry.]
3.3.3.3
hand-held equipment
movable equipment, or a part of any kind of equipment, that is intended to be held in the hand during normal use
3.3.3.4
movable equipment
equipment that is either:
-
18 kg or less in mass and is not fixed equipment; or
-
provided with wheels, casters, or other means to facilitate movement by an ordinary person as required to perform its intended use
3.3.3.5
outdoor equipment
equipment that is installed or exposed in an outdoor location, specified by the manufacturer to comply wholly or in part under specific conditions
Note 1 to entry: Transportable equipment, for example, a laptop or notebook computer, or a telephone, is not outdoor equipment unless specified by the manufacturer for continuous use in an outdoor location.
3.3.3.6
permanently connected equipment
equipment that can only be electrically connected to or disconnected from the mains by the use of a tool
3.3.3.7
pluggable equipment type A
equipment that is intended for connection to the mains via a non-industrial plug and socket-outlet or via a non-industrial appliance coupler, or both
Note 1 to entry: Examples are plugs and socket-outlets covered by standards such as IEC TR 60083 and IEC 60320-1.
3.3.3.8
pluggable equipment type B
equipment that is intended for connection to the mains via an industrial plug and socket-outlet or via an industrial appliance coupler, or both
Note 1 to entry: Examples are plugs and socket-outlets covered by standards such as IEC 60309-1.
3.3.3.9
professional equipment
equipment for use in trades, professions or industries and which is not intended for sale to the general public
[SOURCE: IEC 60050-161:1990, 161-05-05, modified ─ Note deleted.]
3.3.3.10
stationary equipment
-
equipment that, due to its physical characteristics, is normally not moved
Note 1 to entry: Stationary equipment is neither movable equipment nor transportable equipment.
3.3.3.11
transportable equipment
equipment that is intended to be routinely carried
Note 1 to entry: Examples include notebook computers, CD players and portable accessories, including their external power supply units.
3.3.3.12
wireless power transmitter
equipment that uses electromagnetic fields to transfer electrical power for charging battery operated hand-held devices

3.3.4Flammability terms

3.3.4.1
combustible material
material that is capable of being ignited or burned
Note 1 to entry: All thermoplastic materials are considered capable of being ignited or burned regardless of the material flammability class.
3.3.4.2
material flammability class
recognition of the burning behaviour of materials and their ability to extinguish if ignited
Note 1 to entry: Materials are classified when tested in accordance with IEC 60695-11-10, IEC 60695-11-20, ISO 9772 or ISO 9773.
3.3.4.2.1
5VA class material
material tested in the thinnest significant thickness used and classified 5VA according to IEC 60695-11-20
3.3.4.2.2
5VB class material
material tested in the thinnest significant thickness used and classified 5VB according to IEC 60695-11-20
3.3.4.2.3
HB40 class material
material tested in the thinnest significant thickness used and classified HB40 according to IEC 60695-11-10
3.3.4.2.4
HB75 class material
material tested in the thinnest significant thickness used and classified HB75 according to IEC 60695-11-10
3.3.4.2.5
HBF class foamed material
foamed material tested in the thinnest significant thickness used and classified HBF according to ISO 9772
3.3.4.2.6
HF-1 class foamed material
foamed material tested in the thinnest significant thickness used and classified HF-1 according to ISO 9772
3.3.4.2.7
HF-2 class foamed material
foamed material tested in the thinnest significant thickness used and classified HF-2 according to ISO 9772
3.3.4.2.8
V-0 class material
material tested in the thinnest significant thickness used and classified V-0 according to IEC 60695-11-10
3.3.4.2.9
V-1 class material
material tested in the thinnest significant thickness used and classified V-1 according to IEC 60695-11-10
3.3.4.2.10
V-2 class material
material tested in the thinnest significant thickness used and classified V-2 according to IEC 60695-11-10
3.3.4.2.11
VTM-0 class material
material tested in the thinnest significant thickness used and classified VTM-0 according to ISO 9773
3.3.4.2.12
VTM-1 class material
material tested in the thinnest significant thickness used and classified VTM-1 according to ISO 9773
3.3.4.2.13
VTM-2 class material
material tested in the thinnest significant thickness used and classified VTM-2 according to ISO 9773

3.3.5Electrical insulation

3.3.5.1
basic insulation
insulation to provide a basic safeguard against electric shock
Note 1 to entry: This concept does not apply to insulation used exclusively for functional purposes.
3.3.5.2
double insulation
insulation comprising both basic insulation and supplementary insulation
[SOURCE: IEC 60050-195:2021, 195-06-08]
3.3.5.3
functional insulation
insulation between conductive parts which is necessary only for the proper functioning of the equipment
3.3.5.4
insulating liquid
insulating material consisting entirely of a liquid
[SOURCE: IEC 60050-212:2010, 212-11-04]
3.3.5.5
reinforced insulation
single insulation system that provides a degree of protection against electric shock equivalent to double insulation
3.3.5.6
solid insulation
insulation consisting entirely of solid material
[SOURCE: IEC 60050-212:2015, 212-11-02, modified ─ replacement of “insulating material” with “insulation” and replacement of “solid” with “solid material”.]
3.3.5.7
supplementary insulation
independent insulation applied in addition to basic insulation to provide a supplementary safeguard for fault protection against electric shock

3.3.6Miscellaneous

3.3.6.1
accessible
touchable by a body part
Note 1 to entry: A body part is represented by one or more of the probes specified in Annex V, as applicable.
3.3.6.2
backfeed
condition in which a voltage or energy available within a battery backed up supply is fed back to any of the input terminals, either directly or by a leakage path while operating in the stored energy mode and with mains power not available
3.3.6.3
cheesecloth
bleached cotton cloth of approximately 40 g/m2
Note 1 to entry: Cheesecloth is a coarse, loosely woven cotton gauze, originally used for wrapping cheese.
3.3.6.4
coolant
a liquid or gas medium by means of which heat is transferred
[SOURCE: IEC 60050-441:1996, 411-44-02]
3.3.6.5
device
material element or assembly of such elements intended to perform a required function
Note 1 to entry: A device may form part of a larger system (for example, a server node installed in a rack system).
[SOURCE: IEC 60050-151:2001, 151-11-20, modified ─ Addition of the text within parenthesis in Note 1 to entry.]
3.3.6.6
disconnect device
means to electrically disconnect equipment from the mains that, in the open position, complies with the requirements specified for isolation
3.3.6.7
functional earthing
earthing a point or points in a system or in an installation or in equipment, for purposes other than electrical safety
[SOURCE: IEC 60050-195:2021, 195-01-13, modified ─ Addition of “a point or points in a system or in an installation or in equipment”.]
3.3.6.8
liquid cooling system
system that circulates and cools liquid used for decreasing the temperature of a device
[SOURCE: IEC 60050-851:2008, 851-14-48, modified ─ Replacement of “equipment of arc welding and allied processes” with “device”.]
3.3.6.9
liquid filled component
LFC
constituent part of a device which cannot be physically divided into smaller parts without losing its particular function and through which the coolant passes
EXAMPLE        Cold plate, tubing, fittings and interconnects.
[SOURCE: IEC 60050-151:2001, 151-11-21, modified ─ Replacement of the main term “component” with “liquid filled component”, addition of “through which the coolant passes” in the definition, and addition of examples.]
3.3.6.10
liquid filled component assembly
LFC assembly
set of components, at least one of which is a liquid filled component, assembled into a single unit
EXAMPLE        Assembly of cold plate, tubing, fittings and interconnects or any combination thereof.
[SOURCE: IEC 60050-904:2014, 904-01-08, modified ─ Replacement of the main term “electronic assembly” with “liquid filled component assembly”, and in the definition replacement of “an electronic component” with “a liquid filled component”.]
3.3.6.11
loudspeaker driver
transducer by which acoustic waves are obtained from electrical oscillation waves and designed to radiate acoustic power into the surrounding medium
3.3.6.12
modular liquid filled component
modular LFC
device which contains a liquid filled component assembly which relies on external connections to complete the liquid cooling system
EXAMPLE        Examples are cooling distribution unit or facility water system for operation.
3.3.6.13
non-detachable power supply cord
flexible power supply cord affixed to or assembled to the equipment and that cannot be removed from the equipment without the use of tools
3.3.6.14
outdoor location
location for equipment where protection from the weather and other outdoor influences provided by a building or other structure is limited or non-existent
3.3.6.15
pollution degree
numeral characterizing the expected pollution of the micro-environment
[SOURCE: IEC 60050-581:2008, 581-21-07]
3.3.6.16
restricted access area
area accessible only to skilled persons and to instructed persons with the proper authorization
3.3.6.17
routine test
test to which each individual device is subjected during or after manufacture to ascertain whether it complies with certain criteria
[SOURCE: IEC 60664-1:2020, 3.1.42, modified ─ Replacement of “conformity test” with “test”, replacement of “item” with “device”, addition of “to ascertain whether it complies with certain criteria”.]
3.3.6.18
sampling test
test on a number of devices taken at random from a batch
[SOURCE: IEC 60664-1:2020, 3.1.43]
3.3.6.19
self-contained LFC
device which contains a complete liquid cooling system
Note 1 to entry: A self-contained LFC comprising of multiple modular LFCs is considered a modular LFC with regards to G.15.
3.3.6.20
stored energy mode
stable mode of operation that a battery backed up supply attains under specified conditions
Note 1 to entry: In accordance with IEC 62040-1:2017, the specified conditions are as follows:
-
AC input power is disconnected or is out of required tolerance;
-
operating power and output power is supplied by the energy storage device;
-
the load is within the specified rating of the battery backed up supply.
3.3.6.21
subassembly
unit assembled separately and designed to be incorporated with other units into a larger manufactured product and that cannot work independently from the final product
Note 1 to entry: A subassembly shall be regarded as a component in the final product.
3.3.6.22
tool
object that can be used to secure or release a screw, latch or similar fixing means
Note 1 to entry: Examples of tools include coins, tableware, screwdrivers, pliers, etc.
3.3.6.23
touch current
electric current through a human body when body parts touch two or more accessible parts or one accessible part and earth
3.3.6.24
type test
test on a representative sample with the objective of determining if, as designed and manufactured, it can meet the requirements of this document
3.3.6.25
work cell
space within the equipment of such size that a person can enter completely or partially (for example, entire limb or head) for servicing or operating the equipment and where mechanical hazards can be present
Note 1 to entry: A work cell can contain more than one compartment. A compartment can be used for either operational or service purposes.
Note 2 to entry: The equipment containing the work cell is typically installed within a restricted access area.
3.3.6.26
wrapping tissue
tissue between 12 g/m2 and 30 g/m2
Note 1 to entry: The wrapping tissue is soft, thin, usually translucent paper used for wrapping delicate articles.

3.3.7Operating and fault conditions

3.3.7.1
abnormal operating condition
temporary operating condition that is not a normal operating condition and is not a single fault condition of the equipment itself
Note 1 to entry: Abnormal operating conditions are specified in Clause B.3.
Note 2 to entry: An abnormal operating condition can be introduced by the equipment or by a person.
Note 3 to entry: An abnormal operating condition can result in a failure of a component, a device or a safeguard.
3.3.7.2
intermittent operation
operation in a series of cycles, each composed of a period of operation followed by a period with the equipment switched off or running idle
3.3.7.3
non-clipped output power
sine wave power dissipated in the rated load impedance, measured at the test frequency at the onset of clipping on either one or both peaks
Note 1 to entry: See Annex E.
3.3.7.4
normal operating condition
mode of operation that represents as closely as possible the range of normal use that can reasonably be expected
Note 1 to entry: Unless otherwise specified in this document, the most severe conditions of normal use are the most unfavourable default values as specified in Clause B.2.
Note 2 to entry: Reasonably foreseeable misuse is not covered by normal operating conditions. Instead, it is covered by abnormal operating conditions.
3.3.7.5
peak response frequency
test frequency that produces the maximum output power measured at the rated load impedance
Note 1 to entry: The frequency applied should be within the amplifier/transducer’s intended operating range.
3.3.7.6
rated load impedance
impedance or resistance, as declared by the manufacturer, by which an output circuit should be terminated
3.3.7.7
reasonably foreseeable misuse
use of a product, process or service in a way not intended by the supplier, but which can result from readily predictable human behaviour
Note 1 to entry: Reasonably foreseeable misuse is considered to be a form of abnormal operating conditions.
[SOURCE: ISO/IEC Guide 51:2014, 3.7, modified - In the definition, "product or system" has been replaced by "product, process or service". The Notes to entry have been replaced.]
3.3.7.8
short-time operation
operation under normal operating conditions for a specified period, starting when the equipment is cold, the intervals after each period of operation being sufficient to allow the equipment to cool down to room temperature
3.3.7.9
single fault condition
condition of equipment with a fault under normal operating condition of a single safeguard (but not a reinforced safeguard) or of a single component or a device
Note 1 to entry: Single fault conditions are specified in Clause B.4.

3.3.8Persons

3.3.8.1
instructed person
person instructed or supervised by a skilled person as to energy sources and who can responsibly use equipment safeguards and precautionary safeguards with respect to those energy sources
Note 1 to entry: Supervised, as used in the definition, means having the direction and oversight of the performance of others.
Note 2 to entry: In Germany, in many cases, a person can only be regarded as an instructed person if certain legal requirements are fulfilled.
3.3.8.2
ordinary person
person who is neither a skilled person nor an instructed person
[SOURCE: IEC 60050-826:2022, 826-18-03]
3.3.8.3
skilled person
person with relevant education or experience to enable him or her to identify hazards and to take appropriate actions to reduce the risks of injury to themselves and others
Note 1 to entry: In Germany, in many cases, a person can only be regarded as a skilled person if certain legal requirements are fulfilled.
[SOURCE: IEC 60050-826:2022, 826-18-01, modified - The definition has been made applicable to all types of hazards, and a new Note 1 to entry has been added.]

3.3.9Potential ignition sources

3.3.9.1
potential ignition source
PIS
location where electrical energy can cause ignition
3.3.9.2
arcing PIS
PIS where an arc can occur due to the opening of a conductor or a contact
Note 1 to entry: An electronic protection circuit or additional constructional measures may be used to prevent a location from becoming an arcing PIS.
Note 2 to entry: A faulty contact or interruption in an electric connection that can occur in conductive patterns on printed boards is considered to be within the scope of this definition.
3.3.9.3
resistive PIS
PIS where a component can ignite due to excessive power dissipation
Note 1 to entry: An electronic protection circuit or additional constructional measures may be used to prevent a location from becoming a resistive PIS.

3.3.10Ratings

3.3.10.1
rated current
input current of the equipment, as declared by the manufacturer, at normal operating conditions
3.3.10.2
rated frequency
supply frequency or frequency range as declared by the manufacturer
3.3.10.3
rated power
input power of the equipment, as declared by the manufacturer, at normal operating conditions
3.3.10.4
rated voltage
value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
Note 1 to entry: Equipment may have more than one rated voltage value or may have a rated voltage range.
[SOURCE: IEC 60664-1:2020, 3.1.17]
3.3.10.5
rated voltage range
supply voltage range, as declared by the manufacturer, expressed by its lower and upper rated voltages
3.3.10.6
protective current rating
current rating of an overcurrent protective device that is in the building installation or in the equipment to protect a circuit

3.3.11Safeguards

3.3.11.1
backfeed safeguard
control scheme that reduces the risk of electric shock due to backfeed
3.3.11.2
basic safeguard
safeguard that provides protection under normal operating conditions and under abnormal operating conditions whenever an energy source capable of causing pain or injury is present in the equipment
3.3.11.3
double safeguard
3.3.11.4
equipment safeguard
safeguard that is a physical part of the equipment
3.3.11.5
installation safeguard
safeguard that is a physical part of a man-made installation
3.3.11.6
instructional safeguard
instruction invoking specified behaviour
3.3.11.7
personal safeguard
personal protective equipment that is worn on the body and that reduces exposure to an energy source
Note 1 to entry: Examples are shields, goggles, gloves, aprons, face masks or breathing apparatus.
3.3.11.8
precautionary safeguard
instructed person behaviour to avoid contact with or exposure to a class 2 energy source based on supervision or instructions given by a skilled person
3.3.11.9
protective bonding conductor
protective conductor in the equipment provided for protective equipotential-bonding of parts required to be earthed for safety purposes
Note 1 to entry: A protective bonding conductor is internal in the equipment.
3.3.11.10
protective conductor
conductor provided for the purposes of safety (for example, protection against electric shock)
[SOURCE: IEC 60050-195:2021, 195-02-09, modified ─ Addition of an example in the definition, and new Note 1 to entry.]
3.3.11.11
protective earthing
earthing a point or points in a system or in an installation or in equipment for purposes of electrical safety
[SOURCE: IEC 60050-195:2021, 195-01-11, modified ─ Addition of ” a point or points in a system or in an installation or in equipment”.]
3.3.11.12
protective earthing conductor
protective conductor connecting a main protective earthing terminal in the equipment to an earth point in the building installation for protective earthing
3.3.11.13
reinforced safeguard
single safeguard that is effective under:
-
normal operating conditions;
-
abnormal operating conditions; and
-
single fault conditions
3.3.11.14
safeguard
physical part or system or instruction specifically provided to reduce the likelihood of pain or injury, or, for fire, to reduce the likelihood of ignition or spread of fire
Note 1 to entry: See Clause 0.5 for further explanation of a safeguard.
3.3.11.15
safety interlock
means to automatically change an energy source to a lower class energy source prior to the potential for transfer of the higher energy to a body part
Note 1 to entry: A safety interlock encompasses the system of components and circuits that are directly involved in the safeguard function, including electro-mechanical devices, conductors on printed boards, wiring and their terminations, etc., as applicable.
3.3.11.16
skill safeguard
skilled person behaviour to avoid contact with or exposure to a class 2 or class 3 energy source based on education and experience
3.3.11.17
supplementary safeguard
safeguard applied in addition to the basic safeguard that is or becomes operational in the event of failure of the basic safeguard

3.3.12Spacings

3.3.12.1
clearance
shortest distance in air between two conductive parts
[SOURCE: IEC 60664-1:2020, 3.1.4]
3.3.12.2
creepage distance
shortest distance along the surface of an insulating material between two conductive parts
[SOURCE: IEC 60664-1:2020, 3.1.5, modified - In the definition, "solid" has been deleted.]

3.3.13Temperature controls

3.3.13.1
temperature limiter
device for limiting the temperature of a system, either below or above a particular value, by controlling, either directly or indirectly, the flow of thermal energy into or out of the system
Note 1 to entry: A temperature limiter may be of the automatic reset or of the manual reset type.
3.3.13.2
thermal cut-off
device for limiting the temperature of a system, under single fault conditions, by controlling, either directly or indirectly, the flow of thermal energy into or out of the system
3.3.13.3
thermostat
device for maintaining the temperature of a system within a range by controlling, either directly or indirectly, the flow of thermal energy into or out of the system

3.3.14Voltages and currents

3.3.14.1
DC voltage
voltage having a peak-to-peak ripple not exceeding 10 % of the average value
Note 1 to entry: Where peak-to-peak ripple exceeds 10 % of the average value, the requirements related to peak voltage are applicable.
3.3.14.2
mains transient voltage
highest peak voltage expected at the mains input to the equipment arising from external transients
3.3.14.3
prospective touch voltage
voltage between simultaneously accessible conductive parts or between one accessible conductive part and earth when those conductive parts are not being touched
[SOURCE: IEC 60050-195:2021, 195-05-09, modified - In the definition, "or between one accessible conductive part and earth" has been added, and “by a human being or livestock” has been deleted.]
3.3.14.4
protective conductor current
current flowing through the protective earthing conductor under normal operating conditions
Note 1 to entry: Protective conductor current was previously included in the term "leakage current".
3.3.14.5
required withstand voltage
peak voltage that the insulation under consideration is required to withstand
3.3.14.6
RMS working voltage
true RMS value of the working voltage
Note 1 to entry: True RMS value of the working voltage includes any DC component of the waveform.
Note 2 to entry: The resultant RMS value of a waveform having an AC RMS voltage A and a DC component voltage B is given by the following formula: graphic RMS value = ( A 2 + B 2 ) 1 / 2
3.3.14.7
temporary overvoltage
overvoltage at mains power frequency of relatively long duration
3.3.14.8
working voltage
voltage across any particular insulation while the equipment is supplied at rated voltage or any voltage in the rated voltage range under normal operating conditions
Note 1 to entry: External transient voltages are disregarded.
Note 2 to entry: Recurring peak voltages are disregarded.

3.3.15Classes of equipment with respect to protection from electric shock

3.3.15.1
class I equipment
equipment with basic insulation used as a basic safeguard, and with protective bonding and protective earthing used as a supplementary safeguard
Note 1 to entry: Class I equipment may be provided with class II construction.
[SOURCE: IEC 60050-851:2008, 851-15-10, modified - The definition has been adapted to the safeguard principle; new Note 1 to entry.]
3.3.15.2
class II construction
part of an equipment for which protection against electric shock relies upon double insulation or reinforced insulation
3.3.15.3
class II equipment
equipment in which protection against electric shock does not rely on basic insulation only, but in which a supplementary safeguard is provided, there being no provision for protective earthing or reliance upon installation conditions
3.3.15.4
class III equipment
equipment in which protection against electric shock relies upon supply from ES1 and in which ES3 is not generated

3.3.16Chemical terms

3.3.16.1
consumable material
material that is used by the equipment in performing its intended function, and intended to be periodically or occasionally replaced or replenished, including any material that has a life expectancy less than that of the equipment
Note 1 to entry: Air filters are not considered to be consumable materials.
3.3.16.2
explosion
chemical reaction of any chemical compound or mechanical mixture that, when initiated, undergoes a very rapid combustion or decomposition, releasing large volumes of highly heated gases that exert pressure on the surrounding medium
Note 1 to entry: Explosion can also be a mechanical reaction in which failure of the container causes sudden release of pressure, and the contents, from within a pressure vessel. Depending on the rate of energy release, an explosion can be categorized as a deflagration, a detonation or pressure rupture.
3.3.16.3
explosive
substance or mixture of substances that can undergo a rapid chemical change with or without an outside source of oxygen, generating large quantities of energy generally accompanied by hot gases
3.3.16.4
hazardous substance
substance that has the potential for adversely impacting human health
Note 1 to entry: The criteria for determining whether a substance is classified as hazardous are usually defined by law or regulation.

3.3.17Batteries

3.3.17.1
battery
assembly of one or more cells ready for use as a source of electrical energy characterized by its voltage, size, terminal arrangement, capacity and rate capability
Note 1 to entry: A battery pack is considered to be a battery.
3.3.17.2
cell
basic manufactured unit providing a source of electrical energy by direct conversion of chemical energy, that consists of electrodes, separators, electrolyte, container and terminals
3.3.17.3
coin or button cell battery
small, single cell battery having a diameter greater than its height
3.3.17.4
highest specified charging temperature
highest surface temperature on the cells within the battery specified by the manufacturer during charging of a secondary battery
Note 1 to entry: It is assumed that the end-product manufacturer is responsible to specify the safety-sensitive temperature, voltage or current of the battery, based on the specifications provided by the battery supplier.
3.3.17.5
lowest specified charging temperature
lowest surface temperature on the cells within the battery specified by the manufacturer during charging of a secondary battery
Note 1 to entry: It is assumed that the end-product manufacturer is responsible to specify the safety sensitive temperature, voltage or current of the battery, based on the specifications provided by the battery supplier.
3.3.17.6
maximum specified charging current
highest charging current specified by the manufacturer during the charging of a secondary battery
3.3.17.7
maximum specified charging voltage
highest charging voltage specified by the manufacturer during the charging of a secondary battery
3.3.17.8
secondary lithium battery
battery that incorporates one or more secondary lithium cells
Note 1 to entry: Examples of a secondary lithium battery include a rechargeable lithium-ion battery, a rechargeable lithium-polymer battery and a rechargeable lithium metal or alloy battery.

3.3.18FIW terms

3.3.18.1
fully insulated winding wire
FIW
polyurethane enamelled round copper wire, class 180
Note 1 to entry: The insulating properties are in accordance with IEC 60317-0-7, IEC 60317-56 and IEC 60851-5:2008. These standards also refer to this type of wire as "zero-defect wire", which they define as "winding wire that exhibits no electrical discontinuities when tested under specific conditions".
Note 2 to entry: The term "zero-defect wire" is commonly used to refer to FIW.
3.3.18.2
grade of FIW
range of overall diameter of a wire (FIW3 to FIW9)

3.3.19Sound exposure

3.3.19.1
calculated sound dose
CSD
one week rolling estimate of sound exposure expressed as a percentage of the maximum regarded as safe
Note 1 to entry: See B.4 of EN 50332-3:2017 for additional information.
3.3.19.2
momentary exposure level
MEL
metric for estimating 1 s sound exposure level from a specific test signal applied to both channels, based on EN 50332-1:2013, 4.2
Note 1 to entry: MEL is measured in dB(A).
Note 2 to entry: See B.3 of EN 50332-3:2017 for additional information.
3.3.19.3
sound exposure
E
A-weighted sound pressure (p) squared and integrated over a stated period of time, T graphic E = ∫ 0 T p ( t ) 2 d t
Note 1 to entry: The SI unit is Pa2 s.
3.3.19.4
sound exposure level
SEL
logarithmic measure of sound exposure relative to a reference value, E0 graphic SEL = 10   log 10 ( E E 0 )
Note 1 to entry: SEL is measured in dB(A).
Note 2 to entry: The reference value E0 is typically the 1 kHz threshold of hearing in humans.
Note 3 to entry: See B.4 of EN 50332-3:2017 for additional information.
3.3.19.5
digital signal level relative to full scale
dBFS
level of a DC-free 997 Hz sine wave whose undithered positive peak value is positive digital full scale, leaving the code corresponding to negative digital full scale unused
Note 1 to entry: Levels reported in dBFS are always RMS.
Note 2 to entry: It is invalid to use dBFS for non-RMS levels. Because the definition of full scale is based on a sine wave, the level of signals with a crest factor lower than that of a sine wave may exceed 0 dBFS. In particular, square-wave signals can reach +3,01 dBFS.
30mm
20mm
15mm
15mm
10mm
17mm

Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
Gulf StandardGSO IEC 62368-1:2024
GSO IEC 62368-1:2024Gulf Standard
Bibliography
IEC Guide 117:2010, Electrotechnical equipment - Temperatures of touchable hot surfaces
IEC 60050 (all parts), International Electrotechnical Vocabulary (IEV), available at http://www.electropedia.org
IEC 60050-151, International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 60050-161, International Electrotechnical Vocabulary (IEV) - Part 161: Electromagnetic compatibility
IEC 60050-195, International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock
IEC 60050-212, International Electrotechnical Vocabulary (IEV) - Part 212: Electrical insulating solids, liquids and gases
IEC 60050-441, International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 60050-826, International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
IEC 60050-851, International Electrotechnical Vocabulary (IEV) - Part 851: Electric welding
IEC 60050-904, International Electrotechnical Vocabulary (IEV) - Part 904: Environmental standardization for electrical and electronic products and systems
IEC 60065:2014, Audio, video and similar electronic apparatus - Safety requirements
IEC 60079-10-1:2020, Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
IEC 60130-9, Connectors for frequencies below 3 MHz - Part 9: Circular connectors for radio and associated sound equipment
IEC 60169-3, Radio-frequency connectors - Part 3:Two-pin connector for twin balanced aerial feeders
IEC 60204-1, Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC 60204-11, Safety of machinery - Electrical equipment of machines - Part 11: Requirements for equipment for voltages above 1 000 V AC or 1 500 V DC and not exceeding 36 kV
IEC 60269-2, Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K
IEC 60268-2:1987, Sound system equipment - Part 2: Explanation of general terms and calculation methods
IEC 60268-2:1987/AMD1:1991
IEC 60268-3:2018, Sound system equipment - Part 3: Amplifiers
IEC 60268-5:2003, Sound system equipment - Part 5: Loudspeakers
IEC 60268-5:2003/AMD1:2007
IEC 60309-1, Plugs, fixed or portable socket-outlets and appliance inlets for industrial purposes - Part 1: General requirements
IEC 60335-2-40:2022, Household and similar electrical appliances - Safety - Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers
IEC 60364 (all parts), Low-voltage electrical installations
IEC 60364-4-43, Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent
IEC 60364-4-44:2007, Low-voltage electrical installations - Part 4-44: Protection for safety -Protection against voltage disturbances and electromagnetic disturbances
IEC 60364-4-44:2007/AMD1:2015
IEC 60364-4-44:2007/AMD2:2018
IEC 60364-5-53, Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection for safety, isolation, switching, control and monitoring
IEC 60364-5-54, Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors
IEC 60479-1:2018, Effects of current on human beings and livestock - Part 1: General aspects
IEC 60479-2:2019, Effects of current on human beings and livestock - Part 2: Special aspects
IEC 60601-2-4, Medical electrical equipment - Part 2-4: Particular requirements for the basic safety and essential performance of cardiac defibrillators
IEC 60664-1:2020, Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
IEC 60664-4:2005, Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress
IEC 60721-3-4, Classification of environmental conditions - Part 3-4: Classification of groups of environmental parameters and their severities - Stationary use at non-weatherprotected locations
IEC 60906-3, IEC System of plugs and socket-outlets for household and similar purposes - Part 3: SELV plugs and socket-outlets, 16 A 6V, 12 V, 24 V, 48 V, AC and DC
IEC 60950-1:2005, Information technology equipment - Safety - Part 1: General requirements
IEC 61000-4-5:2014, Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-5:2014/AMD1:2017
IEC 61010-2-011, Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-011: Particular requirements for refrigerating equipment
IEC 61032:1997, Protection of persons and equipment by enclosures - Probes for verification
IEC 61140:2016, Protection against electric shock - Common aspects for installation and equipment
IEC TS 61201:2007, Use of conventional touch voltage limits - Application guide
IEC 61439-5:2014, Low-voltage switchgear and controlgear assemblies - Part 5: Assemblies for power distribution in public networks
IEC 61508-1, Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements
IEC 61558-2-1, Safety of transformers, reactors, power supply units and combinations thereof - Part 2-1: Particular requirements and tests for separating transformers and power supply units incorporating separating transformers for general applications
IEC 61558-2-4, Safety of transformers, reactors, power supply units and combinations thereof - Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers for general applications
IEC 61558-2-6, Safety of transformers, reactors, power supply units and combinations thereof - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers for general applications
IEC 61643-21, Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods
IEC 61643-311, Components for low-voltage surge protective devices - Part 311: Performance requirements and test circuits for gas discharge tubes (GDT)
IEC 61643-321, Components for low-voltage surge protective devices - Part 321: Specifications for avalanche breakdown diode (ABD)
IEC 61643-341, Components for low-voltage surge protection - Part 341: Performance requirements and test circuits for thyristor surge suppressors (TSS)
IEC 61969-3, Mechanical structures for electrical and electronic equipment - Outdoor enclosures - Part 3: Environmental requirements, tests and safety aspects
IEC 62040-1:2017, Uninterruptible power systems (UPS) - Part 1: Safety requirements
IEC TR 62102, Electrical safety - Classification of interfaces for equipment to be connected to information and communications technology networks
IEC 62151:2000, Safety of equipment electrically connected to a telecommunication network
IEC 62305-1, Protection against lightning - Part 1: General principles
IEC 62310-1:2005, Static transfer systems (STS) - Part 1: General and safety requirements
IEC TR 62368-2:20—, 9 Audio/video, information and communication technology equipment - Part 2: Explanatory information related to IEC 62368-1:2018
IEC 62368-3, Audio/video, information and communication technology equipment - Part 3: Safety aspects for DC power transfer through communication cables and ports
IEC 62911, Audio, video and information technology equipment - Routine electrical safety testing in production
ISO/IEC Guide 37, 10 Instructions for use of products by consumers
ISO/IEC Guide 51, Safety aspects - Guidelines for their inclusion in standards
ISO 4628-3, Paints and varnishes - Evaluation of degradation of coatings - Designation of quantity and size of defects, and of intensity of uniform changes in appearance - Part 3: Assessment of degree of rusting
ISO 10218-1, Robots and robotic devices - Safety requirements for industrial robots - Part 1: Robots
ISO 10218-2, Robots and robotic devices - Safety requirements for industrial robots - Part 2: Robot systems and integration
ISO 13482, Robots and robotic devices - Safety requirements for personal care robots
ISO 13850, Safety of machinery - Emergency stop function - Principles for design
ITU-T Recommendation K.27, Bonding configurations and earthing inside a telecommunication building
ITU-T Recommendation K.44:2019, Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents - Basic Recommendation
ITU-T P.360, Efficiency of devices for preventing the occurrence of excessive acoustic pressure by telephone receivers and assessment of daily noise exposure of telephone users
ACIF G624:2005, Network interface voltage levels, Australia
AS/NZS 3112, Approval and test specification - Plugs and socket-outlets
ASTM D3278, Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus
ASTM D3828, Standard Test Methods for Flash Point by Small Scale Closed Cup Tester - eLearning Course
ASTM D93, Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester
ASTM E659, Standard Test Method for Autoignition Temperature of Chemicals
BS 1363, 13 A plugs, socket-outlets, adaptors and connection units - Specification for rewirable and non-rewirable 13 A fused plugs
CFR 21, Part 1020, Code of Federal Regulations (USA) Part 1020: Performance standards for ionizing radiation emitting products
Consolidated Regulations of Canada (CRC), c.1370, Radiation Emitting Devices Regulations
EN 71-1:2011, Safety of toys - Part 1: Mechanical and physical properties
EN 50491-3:2009, General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) - Part 3: Electrical safety requirements
UL 2556, UL standard for safety wire and cable test methods
European Council Directive 2013/59/Euratom of 5 December 2013 laying down basic safety standards for protection against the dangers arising from exposure to ionising radiation
European Council Directive 96/29/Euratom of 13 May 1996 laying down basic safety standards for the protection of the health of workers and the general public against the danger arising from ionising radiation
International Commission on Radiological Protection (ICRP) Publication 60:1990 Recommendations of the International Commission on Radiological Protection
30mm
20mm
15mm
15mm
10mm
17mm
INTERNATIONALELECTROTECHNICALCOMMISSION3, rue de VarembéPO Box 131CH-1211 Geneva 20SwitzerlandTel: +41 22 919 02 11info@iec.chwww.iec.ch

1This publication was withdrawn and replaced with IEC 63294:2021.
2This publication was withdrawn and replaced with IEC 63294:2021.
3This publication was withdrawn and replaced with IEC 63294:2021.
9Under preparation. Stage at the time of publication: IEC TDTR 62368-2:2020.
10This publication was withdrawn.